4.3.1
Removing and Replacing a FRU
1. From the XSCF Shell prompt, type the replacefru command.
CODE EXAMPLE 4-1
XSCF> replacefru
----------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. FAN
2. PSU
----------------------------------------------------------------
Select [1,2|c:cancel] :1
----------------------------------------------------------------
Maintenance/Replacement Menu
Please select a FAN to be replaced.
No. FRU Status
--- --------------- ------------------
1. FAN_A#0
2. FAN_A#1
3. FAN_A#2
4. FAN_A#3
----------------------------------------------------------------
Select [1-4|b:back] :1
You are about to replace FAN_A#0.
Do you want to continue?[r:replace|c:cancel] :r
Please confirm the CHECK LED is blinking.
If this is the case, please replace FAN_A#0.
After replacement has been completed, please select[f:finish] :f
replacefru command
(Fan Unit)
(Power Supply Unit)
Faulted
Normal
Normal
Normal
Chapter 4
FRU Replacement Preparation
4-7