Rated Input Current
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements
1
for use in the countries of the European Union. The active power factor corrected power supply also has the added benefit of
not requiring an input voltage range select switch.

SFF specifications

Chassis (in the desktop position)
Height
Width
Depth
Approximate Weight
Weight Supported (maximum distributed load in desktop position)
Temperature Range
Operating
Nonoperating
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options
installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating
Nonoperating
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Standard Efficiency
High Efficiency
1
5.5A
3.95 in
13.3 in
14.9 in
16.7 lb
77 lb
50° to 95°F
-22° to 140°F
10-90%
5-95%
10,000 ft
30,000 ft
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
240W STD active PFC
240W 92% efficient active PFC / 240W 90%
efficient active PFC
10.0 cm
33.8 cm
37.9 cm
7.6 kg
35 kg
10° to 35°C
-30° to 60°C
10-90%
5-95%
3048 m
9144 m
SFF specifications
229

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prodesk 600 g1 towerProdesk 600 g1 small form factor

Table of Contents