Frymaster KSCF18G Installation, Operation & Service Parts Manual page 45

Cool zone series gas fryer
Table of Contents

Advertisement

7.2 Fryer Troubleshooting (cont.)
Actual frypot temperature
7.2.3
differs
(cont.)
setpoint temperature.
Temperature
Probe
KSCF18G COOL ZONE SERIES GAS FRYERS
CHAPTER 7: TROUBLESHOOTING
from
computer
High-Limit
Probe
Temperature Probe
Probe Bracket
Burner Tube
5. The thermometer temperature should be
within ±10°F (±5°C) of the computer
display temperature.
Yes: System is maintaining temperature
properly.
No: Ensure the probe tip is ⅛" from the
top of the burner tubes (see illustration).
If the probe adjustment is correct, the
computer probe circuit may be faulty. If
probe adjustment is incorrect, it will
require adjustment.
6. Contact your authorized service agent if
any of the following occurs during this
test:
a. Computer probe circuit is suspected
as faulty.
b. Temperature
adjustment.
c. Computer fails to call for heat
during the calibration test.
7-3
probe
requires

Advertisement

Table of Contents
loading

Table of Contents