Adjusting The Paper Sensor - SATO CLLM Basic 412e Operator's Manual

Table of Contents

Advertisement

SECTION 2: INSTALLATION
2.3 LOADING LABELS AND TAGS (CONT'D)

2.3.3 Adjusting the Paper Sensor

Adjustment of the paper sensors (I-mark and Gap sensors) is usually not necessary, but the
procedure is described here when you need to make adjustments.
1. Lift up the main cover. Make sure that the cover is pushed upwards until it locks firmly in place
so that it will not fall downwards and injure your hands.
2. The sensor assembly is located just under the
Label Guide Shaft. Turn the purple Sensor
Adjustment knob to adjust the sensors' position.
3. After adjustment, feed a few labels and do a test
print to see if the sensor is working properly.
Adjust the label pitch if necessary.
Caution
When closing the front cover, be careful not to injure your fingers
due to a sudden release of the heavy cover.