9.3 CO [3]
Default
All outside (CO) lines: 600 ms
Value Range
80 ms, 100 ms, 160 ms, 300 ms, 600 ms, 900 ms, 1200 ms
Programming Manual References
[418] Flash/Recall Time
Feature Manual References
1.1.56 External Feature Access (EFA)
1.1.60 Flash/Recall

Automatic Line Access

Specifies which outside (CO) line is seized automatically when an extension user dials the Automatic Line
Access number (9).
Default
All outside (CO) lines: On
Value Range
On (checked), Off (unchecked)
Programming Manual References
[419] Automatic Designated Line Access
Feature Manual References
1.1.72 Line Access, Automatic
1.1.76 Line Preference—Outgoing
CPC Signal Detection—Incoming
Selects the length of time required by the PBX to detect a calling party control (CPC) signal from an
incoming outside (CO) line call before disconnecting the line.
Default
All outside (CO) lines: 350 ms
Value Range
Disable, 22–614 ms in 8 ms increments
Programming Manual References
[420] CPC Signal Detection—Incoming
Feature Manual References
1.1.31 Calling Party Control (CPC) Signal Detection