Viessmann VITODENS 200-W Service Instructions Manual page 115

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Repairs
(cont.)
Extension kit for heating circuit with mixer
Checking the setting of rotary selec-
tor S1
The rotary selector on the PCB of the
extension kit defines the assignment to
the relevant heating circuit.
Heating circuit
Heating circuit with
mixer M2 (heating cir-
cuit 2)
Heating circuit with
mixer M3 (heating cir-
cuit 3)
Checking the rotational direction of
the mixer motor
After being switched ON, the boiler
implements a self-test. During this, the
mixer is opened and closed again.
Changing the rotational direction of the mixer motor (if required)
gS
|
BU
~
Note the rotational direction of the mixer
motor during its self-test.
Then set the mixer manually to "Open"
again.
Note
The flow temperature sensor must now
capture a higher temperature. If the tem-
Rotary
perature drops, either the motor is turn-
selector S1
ing in the wrong direction or the mixer set
setting
is incorrectly fitted.
2
4
1. Remove the upper casing cover of
the extension kit.
2. At plug gS, swap the cores at termi-
nals "|" and "~".
Troubleshooting
Mixer installation instructions
Danger
An electric shock can be life-
threatening.
Before opening the boiler, dis-
connect from the mains volt-
age, for example at the fuse or
the main isolator.
115