Viessmann VITODENS 200-W Service Instructions Manual page 98

Wall mounted gas condensing boiler natural gas and lpg version
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Dis-
Const.
Weath.-
played
comp.
fault
code
48
X
4C
X
50
X
X
58
X
X
90
X
X
91
X
X
92
X
X
93
X
X
94
X
X
98
System char-
Cause
acteristics
Mixer closes
Lead break,
flow tempera-
ture sensor,
heating circuit
2 (with mixer)
Mixer closes
Lead break,
flow tempera-
ture sensor,
heating circuit
3 (with mixer)
No DHW heat-
Short circuit,
ing
cylinder tem-
perature sen-
sor
No DHW heat-
Lead break,
ing
cylinder tem-
perature sen-
sor
Control mode
Short circuit,
temperature
sensor /
Control mode
Short circuit,
temperature
sensor aÖ
No DHW heat-
Short circuit,
ing
collector tem-
perature sen-
sor
Control mode
Short circuit,
cylinder tem-
perature sen-
sor
No DHW heat-
Short circuit,
ing
cylinder tem-
perature sen-
sor
Measures
Check flow temper-
ature sensor
Check flow temper-
ature sensor
Check the cylinder
temperature sen-
sor (see
page 111)
Check the cylinder
temperature sen-
sor (see
page 111)
Check sensor /
on the solar control
module
Check sensor aÖ
on the solar control
module
Check temperature
sensor & on the
solar control mod-
ule or the Vitosolic
sensor
Check temperature
sensor at connec-
tion S3 to the
Vitosolic 100
Check temperature
sensor % on the
solar control mod-
ule or the Vitosolic
sensor