Voltage Selection

The P6T Transmitter can be internally modified to
operate from 230 Vac, 50/60 Hz power.
Voltages in this equipment are hazardous to
life. No user-serviceable parts inside. Refer all
servicing to qualified service personnel.
The safety certifications of the P6T do not
apply when the operating voltage is changed
from the factory setting.
To change the operating voltage, follow these steps.
1. Disconnect the P6T from the ac power source.
2. Remove the eight Phillips head screws securing the top
cover.
3. Locate Voltage Selector switch SW4 adjacent to power
transformer T1 and, using a screwdriver, turn the center
rotor to the 230 V position.
4. Locate fuse and remove it. Replace it with a 80 mA, 250 V,
time delay fuse for 230-volt operation (160 mA, 250 V,
time delay fuse for 115-volt operation).
Fuse part numbers are:
Fuse Type
Shure Part No.
80 mA, 250 V
time delay
160 mA, 250 V
time delay
5. Replace the power cord with a cord rated for for 230 V
operation, i.e., an IEC appliance connector on the
equipment end and a CEE 7/7 ("Schuko") mains
connector on the other.* (Shure part #95A8247.)
14
Tip = hot
ring = cold
sleeve = ground
Yes
Up to 60 VDC
. . . . . . . . . .
.
90XJ1371
PA760 (120 VAC)
PA760E (240 VAC)
. . . . . . . . . . . . . . . . . . . . . . .
. . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
WARNING
Part No.
80H380
Schurter
.034.3106
80K258
Littelfuse
218.160

CUSTOM EARPIECES

For information regarding a complete line of custom
made musicians' earpieces, contact:
Ultimate Ears Inc.
2657 Windmill Pkwy. #391
Henderson, NV 89014
(702) 263–7805
PA710
(702) 896–8856 (fax)
PA715
www.ultimateears.com
PA745
UA802
Firehouse Productions, Inc.
12 Boice Road
Hyde Park, NY 12538
(914) 229–2055
(914) 229–0844 (fax)
PA705
Sensaphonics
PA725
660 N. Milwaukee
PA750
Chicago, IL 60622
PA755
(312) 660–1714
(312) 432–1783 (fax)
Similarly, the EP6T can be internally modified
operate from 115 Vac, 50/60 Hz power.
To change the operating voltage, follow these steps.
1. Disconnect the EP6T from the ac power source.
2. Remove the eight Phillips head screws securing the top
cover.
3. Locate Voltage Selector switch SW4 adjacent to power
transformer T1 and, using a screwdriver, turn the center
rotor to the 115 V position.
4. Locate fuse and remove it. Replace it with a 160 mA, 250
V, time delay fuse for 115-volt operation (80 mA, 250 V,
time delay fuse for 230-volt operation).
Fuse part numbers are:
Fuse Type
160 mA, 250 V
time delay
80 mA, 250 V
time delay
5. Replace the power cord with a cord rated for for 115 V
operation, i.e., an IEC appliance connector on the
equipment end and a mains connector suitable for 115 V
operation on the other.* (Shure part #95A8389.)
*For systems requiring other mains connectors, obtain a power cord with
an IEC 320 type mating connector for connection to the P6T, and an
appropriate plug on the other end for connection to the mains. The supplied
cord uses Harmonized IEC Cordage with color coding as follows: Brown =
Line, Blue = Neutral, Green/Yellow = Ground.
Shure Part No.
Part No.
80K258
Littelfuse
218.160
80H380
Schurter
.034.3106
to