No. Trap Name
63
alaErpRingMultipleRpl
alaErpRingId—The unique Ring identifier.
64
alaErpRingRemoved
alaErpRingId—The unique Ring identifier.
65
ntpMaxAssociation
NtpMaxAssociation—The maximum number of peer and client associations that the switch will serve.
66
ddmTemperatureThresholdViolated
ifIndex—The interface index.
ddmNotificationType—The trap type for monitored DDM parameters (clearViolation(1), highAlarm(2), high-
Warning(3), lowWarning(4), lowAlarm(5).
ddmTemperature—The temperature, in tenths of a degree celcius.
67
ddmVoltageThresholdViolated
ifIndex—The interface index.
ddmNotificationType—The trap type for monitored DDM parameters (clearViolation(1), highAlarm(2), high-
Warning(3), lowWarning(4), lowAlarm(5)
ddmSupplyVoltage—The voltage, in tenths of a volt.
68
ddmCurrentThresholdViolated
ifIndex—The interface index.
ddmNotificationType—The trap type for monitored DDM parameters (clearViolation(1), highAlarm(2), high-
Warning(3), lowWarning(4), lowAlarm(5).
ddmTxBiasCurrent—The current Transmit Bias Current of the SFP/XFP in 10s of milli-Amperes (mA).
OmniSwitch AOS Release 7 Switch Management Guide
Objects
Family
alaErpRingId
erp
alaErpRingId
erp
ntp
ifIndex
ddmNotifica-
tionType
ddmTempera-
ture
ifIndex
port
ddmNotifica-
tionType
ddmSupplyVolt-
age
ifIndex,
port
ddmNotifica-
tionType
ddmTxBiasCur-
rent
March 2011
SNMP Traps Table
Description
This trap is sent when multiple
RPLs are detected in the Ring.
This trap is sent when the Ring is
removed dynamically.
This trap is generated when the
the maximum number of peer
and client associations config-
ured for the switch is exceeded.
This trap is sent when an SFP/
XFP/SFP+ temperature has
crossed any threshold or
reverted from previous threshold
violation for a port represented
by ifIndex. It also provides the
current realtime value of SFP/
XFP/SFP+ temperature.
This trap is sent when SFP/XFP/
SFP+ supply voltage has crossed
any threshold or reverted from
previous threshold violation for a
port represented by ifIndex. It
also provides the current realtime
value of SFP/XFP/SFP+ supply
voltage.
This trap is sent when if an SFP/
XFP/SFP+ Tx bias current has
crossed any threshold or reverted
from previous threshold violation
for a port represented by ifIndex.
It also provides the current real-
time value of SFP/XFP/SFP+ Tx
bias current.