SYSTEM TIMERS
You can set various timers from the Programming Extension to suit your requirements.
•
From the Programming Extension, press the PROGRAM Key
•
Press the Scroll Down Key ( ) until 'System programming' is displayed
•
Select 'System programming'
•
Enter the System Programming Password
•
Select 'System'
•
Press the Scroll Down Key ( ) until 'Timers' is displayed
•
Select 'Timers'
•
Select the required timer to be changed and enter the duration. (See table below)
•
Confirm the new time.
Press the Hands-free Key to finish programming.
Timers
Recall on hold
Recall on transfer
Divert on no answer
Courtesy delay
Open the door
Door Intercom ring duration
Call park
Ringback time duration
Auto Attendant Day
Auto-Attendant Night
Answer machine delay
Voicemail message length
AA dial time
Hunt timer
Notification Delay
Notification Interval
Courtesy service length
Recall on Hold
This is the time that elapses before a call, which has been placed on hold, rings back the
extension that put the call on hold.
Recall on transfer
This is the time that elapses before a call, which has been transferred and not answered,
rings back the extension that attempted the transfer.
Divert on no answer
This is the time that elapses before a call ringing at an extension, with 'Divert On No Answer'
set, is diverted.
Courtesy delay
This is the time that elapses before an unanswered incoming call is presented the courtesy
message.
Open the door
This is the time that the Doorstrike relay will remain open following activation.
108
Range
Default setting
001 – 1800
90 seconds
001 – 300
30 seconds
01 – 30
11 seconds
01 – 30
30 seconds
01 – 30
5 seconds
01 – 30
30 seconds
001 – 300
180 seconds
01 – 30
30 seconds
01 – 30
1 seconds
(immediate answer)
01 – 30
1 seconds
(immediate answer)
01 – 30
10 seconds
30 - 300
60 seconds
01 - 05
2 seconds
001 - 300
15 seconds
060 – 1800
900 seconds
060 – 900
300
001-300
180 seconds