The Windows® operating system is shut down.
The Windows® operating system locks-up.

Terminal Services troubleshooting

If you are experiencing problems with iLO Terminal Services Pass-through, check the following:
Verify that Terminal Services is enabled on the host by selecting My
1.
Computer>Properties>Remote>Remote Desktop.
Verify that the iLO pass-through configuration is enabled or automatic by checking iLO Global
2.
Settings.
Verify whether iLO Advanced functionality is licensed.
3.
Verify whether the iLO Management Interface Driver is installed on the host by selecting My
4.
Computer>Properties>Hardware>Device Manager>Multifunction Adapters.
Verify if Terminal Services pass-through service and iLO Proxy is installed and running on the host by
5.
selecting Control Panel>Administrative Tools>Services and attempting to restart the service.
Determine whether the Application Event Log is full.
6.
The Terminal Services Pass-through service might experience start-up problems when the operating
system Application Event Log is full. To view the event log, select Computer Management>System
Tools>Event Viewer>Application.
Verify that the Terminal Services port assignment is correct. Verify that the Terminal Services client,
7.
mstsc.exe is located in \WINDOWS\SYSTEM32.
If not, reconfigure the pass-through configuration to Enabled and manually activate the terminal
services client.

iLO Shared Network Port

The iLO Shared Network Port enables you to choose either the system NIC or the dedicated iLO NIC for
server management. Both regular network traffic and network traffic intended for iLO pass through the
system NIC when this feature is selected. The iLO Shared Network Port is only available on a limited
number of ProLiant servers, as shown in the "iLO Shared Network Port requirements (on page 40)"
section.
Not all iLO management features are available when using the iLO Shared Network Port. Refer to the
"iLO Shared Management Port features and restrictions (on page 41)" section for a list of supported and
unsupported iLO management features.

iLO Shared Network Port requirements

The iLO Shared Network Port feature is only available on servers with hardware that supports this feature.
In addition to the hardware, both the NIC and iLO firmware must support the feature.
ProLiant server
DL320G3
DL360 G4
DL360 G4
DL380 G4
Minimum iLO firmware version
1.64
1.60
1.64
1.60
Configuring iLO 40