Proliant Bl P-Class Alert Forwarding - HP Integrated Lights-Out User Manual

Integrated lights-out firmware 1.91
Hide thumbs Also See for Integrated Lights-Out:
Table of Contents

Advertisement

Insufficient power notification
iLO turns the Server Health LED solid red if iLO cannot power on the server because insufficient power is
in the rack infrastructure.

ProLiant BL p-Class alert forwarding

iLO supports blade infrastructure SNMP traps on a pass-through basis. Reporting of blade infrastructure
status by iLO does not require operating system support. The alerts (traps) originate from the Enclosure
Manager and Power Supply Manager and are transmitted to iLO. iLO p-Class firmware forwards
infrastructure alerts as SNMP traps to a correctly configured management console. These alerts allow the
monitoring of p-Class alerts to take place in an SNMP management console.
p-Class alert forwarding is disabled by default and can be enabled from the SNMP/Insight Manage
Settings web page.
The following alerts are identified and forwarded by iLO:
Alert ID
22005
22006
22007
22008
22009
22010
22013
22014
22015
22023
Description
Enclosure temperature failure
Enclosure temperature degradation
Enclosure temperature OK
Enclosure fan failed
Enclosure fan degraded
Enclosure fan OK
Rack power failure
Rack power degraded
Rack power supply OK
Rack server failed; not enough power
Using iLO 103