Interlock Switches
1) Optional external interlock switches are required with some
Sectional or Rolling Steel Doors to prevent the door from
operating under certain conditions including the following:
If the door is equipped with a functioning door lock, an
interlock switch must be installed to prevent electric
operation when the lock is engaged.
If the door is equipped with a pedestrian pass-through door,
an interlock switch must be installed at the pass-through
door in order to prevent electrical operation when the
pass-through door is open.
Pass door interlock:
Should be open when
door is open.
Closed when door is
closed.
NOTE: If External Interlock is used, THE JUMPER WIRE BETWEEN THE
EXT INTLK TERMINALS MUST BE REMOVED.
Side lock interlock:
Should be open when door is locked.
Closed when door is unlocked.
GCL-MJ&MH
Medium Duty Operator
OPEN
SWITCH
(N.O.)
ANGLE
Switches must
be set in
the field.
Figure 7
www.geniecompany.com
CONTROL SIGNAL TERMINAL STRIP
ODC
ODC
CLOSE
STOP
GND
1 BTN
STB
STB
SAFETY
SWITCH
(N.C.)
TRACK
08-12
N O
N O
EXT
EXT
SAFETY
INTLK
INTLK
STANDARD
SLIDELOCK
5.5