Wall Control

1) For one 3 - button installation, make connections as
shown in Fig. 4.
2) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
3) For single button accessory controls, make connections as
shown in Fig. 6.
NOTE: If an External STOP button is NOT being installed, a jumper
wire must be installed between the "STOP" AND "GND" terminals
as shown in Fig. 6.
NOTE: Long Distance Relay Kit wiring is not required for long
distance control runs and should not be used
WARNING:
Wall Control(s) must be located so that the door is within
sight of the user and far enough from the door, or positioned,
such that the user is prevented from coming in contact with
the door while operating the controls.
Attach the Warning placard adjacent to the Wall
Control. Fig. 4A .
Attach the Caution label adjacent to the Wall Con
Figure 4
GCL-MJ&MH
Medium Duty Operator
Figure 5
WARNING:
trol.
Fig. 4B.
external reversing device such as a photocell system or sensing edge
switch must be used. See pages 5.6-5.7 for installation of entrapment
protection devices.
Figure 4A
Entrapment
Warning
Placard
11 735
www.geniecompany.com
Figure 6
If momentary contact control is to be used, a monitored
CAUTION
Figure 4B
This door is operated by a limited-duty operator.
To prevent the motor protector from tripping,
do not exceed 15 cycles of opening
and closing per hour.
NOT FOR RESIDENTIAL USE