Run Codes - Genie GCL-MJ&MH Manual

Commercial/industrial door medium duty operator with tensibelt
Table of Contents

Advertisement

Display Run Codes
Condition
DISPLAY
Code
0C
IDLE > DOWN LIMIT
IDLE > UP LIMIT
0D
IDLE > MID STOP
0E
IDLE > NO LIMIT
0F
OPENING > OPEN BTN
10
OPENING > ONE BTN
11
OPENING > RADIO
12
OPENING > AUX OPEN
13
OPENING > OPEN KEY
14
CLOSING > CLOSE PB
20
CLOSING > ONE BTN
21
CLOSING > RADIO
22
CLOSING > CLOSE KP
24
CLOSING > TCM CLS
2A
HALT > WALL BUTTON
30
HALT > ONE BUTTON
31
HALT > RADIO
32
HALT > AUX. OPEN
33
HALT > KEYPAD KEY
34
HALT > N-O SAFETY
35
HALT > ODC STB
36
HALT > N-C SAFETY
37
HALT > MON. EDGE
38
HALT > DOOR FORCE
39
HALT > LOSS OF C/C
3A
HALT > SHUTDOWN
3B
HALT > DOWN LIMIT
3C
HALT > UP LIMIT
3D
HALT > MID STOP
3E
HALT > MODULE FAIL
3F
GCL-MJ&MH
Medium Duty Operator
Section 10: Appendix C
Condition Code Description
STANDING BY AT DOWN LIMIT (NOTE: THIS MESSAGE IS DISPLAYED IF BOTH LIMITS ARE ACTIVE)
STANDING BY AT UP LIMIT
STANDING BY AT MID-STOP LIMIT
STANDING BY BETWEEN LIMITS
OPENING FROM OPEN BUTTON
OPENING FROM 1 BUTTON
OPENING FROM RADIO
OPENING FROM AUXILIARY OPEN INPUT
OPENING FROM KEYPAD OPEN KEY
CLOSING FROM CLOSE BUTTON
CLOSING FROM 1 BUTTON
CLOSING FROM RADIO
CLOSING FROM KEYPAD CLOSE KEY
CLOSING FROM TIMER CLOSE MODULE
GDO STOPPED BECAUSE STOP OR OPEN BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
GDO STOPPED BECAUSE 1 BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
GDO STOPPED BECAUSE RADIO INPUT WAS ACTIVATED, STARTING A REVERSAL
GDO STOPPED BECAUSE AUXILIARY OPEN INPUT WAS ACTIVATED, STARTING A REVERSAL
GDO STOPPED BECAUSE KEYPAD STOP OR OPEN KEY WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
GDO STOPPED BECAUSE N-O REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
GDO STOPPED BECAUSE ODC STB WAS BLOCKED, STARTING A REVERSAL
GDO STOPPED BECAUSE N-C REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
GDO STOPPED BECAUSE MONITORED EDGE SENSOR INPUT WAS ACTIVATED, STARTING A REVERSAL
GDO STOPPED BECAUSE THE FORCE REQUIRED TO OPERATE THE DOOR WAS TOO HIGH, POSSIBLY STARTING A REVERSAL
GDO STOPPED BECAUSE CONSTANT CONTACT ON THE CONTROL WAS REMOVED BEFORE REACHING A LIMIT, POSSIBLY STARTING A REVERSAL
GDO STOPPED BECAUSE THE GDO DETECTED A FAULT SUCH AS AN OPEN INTERLOCK, OVERHEATED MOTOR, ETC.
GDO STOPPED BECAUSE IT REACHED THE DOWN LIMIT
GDO STOPPED BECAUSE IT REACHED THE UP LIMIT
GDO STOPPED BECAUSE IT REACHED THE MID-STOP LIMIT
GDO STOPPED BECAUSE AN EXPANSION MODULE WAS NOT WORKING PROPERLY