Changing Open & Close Modes - Genie GCL-MJ&MH Manual

Commercial/industrial door medium duty operator with tensibelt
Table of Contents

Advertisement

Changing Open and Close Modes
NOTE: Once the travel limit and safety modes have been set, the OPEN and
CLOSE modes may be set for Momentary Contact if desired.
WARNING
If momentary contact control is to be used, a monitored
external reversing device such as a photocell system or sensing
edge switch must be used.
NOTE: The radio control input will not operate when the open or close
mode is set in the Constant Contact mode. Operating modes affect all
control inputs and keys.
To set the OPEN mode: Fig. 12
1) Press CAL/RUN to enter the calibration mode.
2) Press SCROLL ( ) or ( ) until display reads "OPEN MODE > ."
This displays current setting.
3) Press SET/CLEAR until the display reads the desired operating mode:
C-STP = Constant contact is required to open door. Door will
stop if button or key is released before operator reaches its limit.
MOM = Momentary contact will cause door to open to limit.
4) Press CAL/RUN to return to run mode.
To set the CLOSE mode: Fig. 13.
1) Press CAL/RUN to enter the calibration mode.
2) Press SCROLL ( ) or ( ) until display reads "CLOSE MODE > ".
This displays current setting.
3) Press SET/CLEAR until the display reads the desired operating mode:
C-STP = Constant contact is required to close door. Door will
stop if button or key is released before operator reaches its limit.
C-REV = Constant contact is required to close the door. Door
will reverse automatically if close button or key is released
before door reaches down limit.
MOM = Momentary contact will cause door to close to limit.
4) Press CAL/RUN to return to run mode.
GCL-MJ&MH
Medium Duty Operator
.
www.geniecompany.com
OPEN MODE MOM
Figure 12
CLOSE MODE MOM
Figure 13