NOZZLE
PLACEMENT
A) Determine the proper firing rate for the boiler or fumace units, considering the specific application, and then
use the Burner Setup charts on page 15 to select the proper nozzle and pump pressure to obtain the required
input from the burner.
B) Remove
the NOZZLE
ADAPTER
(2) from the DRAWER
ASSEMBLY
by loosening the SCREW (1).
C) Insert the proper
NOZZLE
into the NOZZLE
ADAPTER
and tighten securely (Do not over tighten).
D) Replace
adapter,
with
nozzle
installed,
into
drawer
assembly and secure with screw (1).
INSTALLATION/REMOVAL
OF DRAWER
ASSEMBLY
Removal:
A) Loosen offoil delivery tube nut from pump.
B) Loosen SCREW (3), and then unplug CONTROL BOX (1) by carefully pulling it back and then up.
C) Remove
the AIR TUBE
COVER
PLATE
(5) by loosening the retaining
SCREW
(4) (Two SCREWS
-
Model F5).
D) Loosen SCREW (2), and then slide the complete drawer assembly out of the combustion head as shown.
E) To insert drawer assembly, reverse the procedure in items A to D above.
®