Riello 40 F5 Installation & Operating Manual page 7

40 series residential oil burners, equipped with electronic air shutter
Table of Contents

Advertisement

METHOD
1 - UNIVERSAL
MOUNTING
FLANGE
A) Insert the two BOLTS (1) into the UNIVERSAL
MOUWHNG
FLANGE
(10) from the flat side, ensuring
the bolt heads are flush with the flat surface.
Secure
in place using two special CHROME
NUTS
(2)
provided.
®
/
/
®® ®
A
COMBUSTION
CHAMBER
:
DRY
BASE
BOILER
B) Position
the MOU2,_T1NG GASKET
(3) between
the flat surface
of the UNIVERSAL
MOU2qT1NG
FLANGE
(10) and the appliance.
Line up the holes in the UNIVERSAL
MOUNT1NG
FLANGE
with the
STUDS (4) on the appliance mounting plate and securely bolt the UNIVERSAL
MOU2,_T1NG FLANGE
to
the plate.
C) Secure the two semi-flanges
of the ADJUSTABLE
COLLAR
(9) to the AIR TUBE using the two long
BOLTS (6). Be sure that the ADJUSTABLE
COLLAR
(9) is properly positioned so the outside edge of the
END CONE will be at least */4inch (6.51ran) back from the inside wall of the refractory of the combustion
chamber
(see dimension
B above). The measured
length (A) is to include
MOU_NT1NG GASKET
and
FLANGE, if used.
D) The bumer may now be attached to the heating unit by insetting the AIR TUBE
through the BUNNER
ACCESS HOLE (8) and into the appliance, making sure the BOLTS (1) line up with the two HOLES (5) in
the ADJUSTABLE
COLLAR (9). Secure the burner in place using two NUTS (7).
A visual verification
of the air tube insertion into the combustion
chamber
of the heating unit is suggested.
Dimension B should be at least */4"(see drawing).
NOTE: A suggested
method for creating mounting
bolt holes in the mounting
gasket: Hold the gasket against
the appliance mounting
bolts using the mounting
flange for proper positioning. Lightly tap the flange with a
halraner to form the holes.
METHOD
2 - SEMI-FLANGE
COLLAR
A) Follow item C from METHOD 1.
B) Align the air tube and attached
adjustable collar so air tube is centered in the bumer access hole of the
boiler/furnace unit. Mark the center of the two holes in the ADJUSTABLE
COLLAR on to the front plate of
the heating unit. Then drill */4inch (6.51run) holes through the front plate of the unit, using marks as a guide.
C) Install two short BOLTS
(1) through the front plate of the heating unit from the inside, and secure on the
outside using the two special CHROME NUTS (2).
D) Follow item D from METHOD 1.
Standard 40 F3-F5 I-O manual Rev4 l.doc