Nozzle Placement; Insertion / Removal Of Drawer Assembly - Riello F3 Installation Manual

40 series residential oil burners
Table of Contents

Advertisement

A) Determine the proper firing rate for the boiler or furnace units, considering the specific application, and then
use the Burner Setup charts on page 15 to select the proper nozzle and pump pressure to obtain the required
input from the burner.
B) Remove the NOZZLE ADAPTER (2) from the DRAWER
ASSEMBLY by loosening the SCREW (1).
C) Insert the proper NOZZLE into the NOZZLE ADAPTER
and tighten securely (Do not over tighten).
D) Replace
adapter,
assembly and secure with screw (1).
INSTALLATION/REMOVAL OF DRAWER ASSEMBLY
Removal:
A) Loosen off oil delivery tube nut from pump.
B) Loosen SCREW (3), and then unplug CONTROL BOX (1) by carefully pulling it back and then up.
C) Remove the AIR TUBE COVER PLATE (5) by loosening the retaining SCREW (4) (Two SCREWS –
Model F5).
D) Loosen SCREW (2), and then slide the complete drawer assembly out of the combustion head as shown.
E) To insert drawer assembly, reverse the procedure in items A to D above.
C6501010 STANDARD F3-5 MANUAL Rev. 3-2 10/12/2006

NOZZLE PLACEMENT

with
nozzle
installed,
into
drawer
10

Advertisement

Table of Contents
loading