Maytag BRAVOS MGD6600TQ0 Use & Care Manual page 8

Steam fabric care system gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Gas Supply
Line:
Must include
1/8" NPT minimum
plugged
tapping
accessible
for test gauge connection,
immediately
upstream
of the gas connection
to the dryer (see illustration).
1/2" [PS pipe is recommended.
%" approved
aluminum
or copper
tubing
is acceptable
for lengths
under 20 ft (6.1 m) if
local codes and gas supplier
permit.
If you are using Natural
gas, do not use copper
tubing.
%" flare x %" NPT adapter
fitting between
dryer pipe and %" approved
tubing.
Lengths over 20 ft (6.1 m) should
use larger tubing
and a different
size adapter fitting.
If your dryer has been converted
to use [.P gas, %" ]+P compatible
copper
tubing
can be
used. If the total
length of the supply
line is more than 20 ft (6.1 m), use larger pipe.
NOTE:
Pipe-joint
compounds
that resist the action of EP gas must be used. Do not use
TEFI.ON
'+tape.
Must include
a shutoff
valve:
In the U.S.A.:
An individual
manual shutoff
w_lve must be installed
within
six (6) feet (1.8 m) of the dryer
in accordance
with the National
Fuel (-;as Code, ANSI Z223.1.
In Canada:
An individual
manual
shutoff valve must be installed
in accordance
with
the B149.1,
Natural
Gas and Propane
Installation
Code. It is recommended
that an individual
manual
shutoff
valve be installed
within
six (6) feet 11.8 m) of the dryer.
The location
should
be easy to reach for opening
and closing.
A
C
E
B
D
A. f_" fk'xible
gas connector
B. ?_" pipe
to flare adapter
fitting
C. _"
NPf
minimum
plugged
tapping
D. _/_" NPT gas supply
line
E. Gas shutoff
valve
Gas supply
connection
requirements
Use an elbow
and a %" flare x %" NPT adapter fitting
between
the flexible
gas connector
and the dryer gas pipe, as needed to avoid kinking.
Use only pipe-joint
compound.
Do not use TEFLON
+ tape.
This dryer must be connected
to the gas supply
line with
a listed flexible
gas connector
that complies
with the standard
for connectors
for gas appliances,
ANSI Z21.24
or
CSA 6.10.
Burner
Input
Requirements:
Elevations above 10,000
ft (3,048
m):
When
installed
above 10,000
ft (3,048
r'n) a 4% reduction
of the burner
Btu rating shown
on the model/serial
number
plate is required
for each 1,000 ft (305 m) increase
in
elevation.
Gas Supply Pressure Testing
The dryer must be disconnected
from the gas supply
piping
system during
pressure testing
at pressures greater than +/2psi.
Dryer
Gas Pipe
The gas pipe that comes out through
the rear of your dryer has a %" male pipe thread.
(1.9 cm)
A. %" NP7 dryer pipe
t®TEFLON
is a legistered
trademark
of E.I. Du Pont De Nenlours
and
Company.
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bravos mgd6600tq1

Table of Contents