Maytag BRAVOS MGD6600TQ0 Use & Care Manual page 12

Steam fabric care system gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Levelm
Excessive
Weight
Hazard
Use two or more people
to move and install
dryer.
Failure
to do so can result
in back or other
injury.
1.
[b protect
the floor,
use a large, flat piece of cardboard
from the dryer carton.
Place
cardboard
under the entire back edge of the dryer.
2.
Firmly grasp the body of the dryer (not the top or console
panel).
Gently
lay the dryer on
the cardboard.
See illustration.
t_
2.
Remove the red cap from the gas pipe.
Using a wrench
to tighten,
connect
the gas supply
to the dryer. Use pipe-joint
compound
on the threads of all non-flared
male filings.
[f flexible
metal tubing
is used, be sure there
are no kinks.
A . ...........
.......
A. flar_'d mal_' fl_mad
B. Non-flared
male thread
3_
Examine
the leveling
legs. Find the diamond
marking.
4.
Screw the legs into the leg holes by hand. Use a wrench
to finish turning
the legs until the
diamond
marking
is no longer visible.
5.
Place a carton
corner
post from dryer packaging
under each of the 2 dryer back corners.
Stand the dryer up. Slide the dryer on the corner
posts until it is close to its final location.
leave enough
room to connect
the exhaust
vent.
For mobile
home
use
Gas dryers must be securely
fastened to the floor.
Mobile
home installations
require a Mobile
Home Installation
Kit. See "|bols
and Parts"
section
for information
on ordering.
3_
4_
NOTE:
For [.P gas connections,
you must use pipe-joint
compound
resistant to the action
of [P gas. Do not use TEFLON _'* tape.
A combination
of pipe fittings
must be used to connect
the dryer to the existing
gas line.
Shown is a recommended
connection.
Your connection
may be different,
according
to the
supply
line type, size and location.
!
B
A. _" fle'xibl_"gas connector
B. _" dryer pipe
C. _" to _" pipe elbow
D. _" pipe-to-flare adapter fitting
Open the shutoff valve in the supply
line. The valve is open when the handle
is parallel
to
the gas pipe.
A. Closed valve
B. Open valve
[e'st all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will show a leak. Correct
any leak found.