Venting Requirements; Plan Vent System; Connect Vent - Maytag BRAVOS MGD6600TQ0 Use & Care Manual

Steam fabric care system gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Alternate installations
for close clearances
Venting
systems come
ill many varieties.
Select the type best for your installation.
Two close-
clearance
installations
are shown.
Refer to the manufacturer's
instructions.
L_-I
"__'
A
B
C
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
C. Rear exhaust installation to left or right side
NOTE: The following
kits for close clearance
alternate
installations
are available
for purchase.
Please see the "Assistance
or Service"
section
to order.
Over-the-Top
Installation:
Part Number
4396028
Periscope
Installation
(For use with
dryer vent to wall vent mismatch):
Part Number
4396037
- 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number
4396011
- 18" (45.72
cm) to 29" (7_.66
cm) mismatch
Part Number
4396014
- 29" (/3.66
cm) to bO" (12/
cm) mismatch
Rear exhaust
installation
to left or right side:
Part Number
4396011
Vent extension:
Part Number
8544761
Special
provisions for mobile
home installations
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home. lerminate
the exhaust
vent
outside.
/
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors.
Plan the installation
to use the fewest
number
of elbows
and turns.
When
using elbows
or making
turns, allow
as much room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent length
and elbows
needed
for best drying
performance
Use the following
Vent system chart to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE: Do not use vent runs longer than those specified
in the Vent system chart. Exhaust
systems longer than those specified
will:
Shorten
the life of the dryer.
Reduce
performance,
resulting
in longer drying
times and increased
energy
usage.
[he Vent system chart provides
venting
requirements
that will help to achieve
the best drying
performance.
Vent
system
chart
NOTE: Performance
of rear exhaust to either
side of the dryer is equiw_lent
to adding
one
elbow.
lb determine
maximum
exhaust
length, add one elbow
to the chart.
Number
of
Type of
Box or
Angled
90 ° turns
vent
Louvered
hoods
or elbows
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
Flexible metal
36 ft (11 m)
28 ft/8.5
m)
.............................................................................................................................................................................................................................
1
Rigid metal
54 ft (16.5 m)
48 ft (14.6 m)
Flexible metal
31 ft 19.4 m)
23 ft 17 m)
.............................................................................................................................................................................................................................
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible metal
27 ft (8.2 m)
19 ft 15.8 m)
.............................................................................................................................................................................................................................
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible
metal
25 ft 17.6 m)
17 ft/5.2
m)
.............................................................................................................................................................................................................................
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible metal
23 ft (7 m)
15 ft (4.6 m)
1.
Install exhaust
hood.
Use caulking
compound
to seal exterior
wall opening
around
exhaust
hood.
2.
Connect
vent to exhaust
hood. Vent must fit inside exhaust
hood.
Secure vent to exhaust
hood with 4" (10.2 cm) clamp.
3.
Run vent to dryer location.
Use the straightest
path possible.
See "Determine
vent path" in
"Plan Vent System."
Avoid
90 ° turns.
Use clamps
to seal all joints.
Do not use duct tape,
screws or other fastening
devices that extend
into the interior
of the vent to secure vent.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bravos mgd6600tq1

Table of Contents