10K Series Models
[] How to Instafl the Unit
4,
TO prevent vibration
and noise, make sure
the unit is installed
securely
and firmly
2. Install the unit where the sunlight does not
Cooled
shine directly on the unit.
,
The outside of the cabinet must extend
outward for at least 11" and there should
be no obstacles,
such as a fence or wall,
within 20" from the back of the cabinet
because
it will prevent heat radiation
of the
condenser.
Restriction
of outside air will greatly reduce
the cooling efficiency
of the air conditioner,
Fence
/
/
CAUTION:
All side louvers of the cabinet
must remain ex_s_
to the outside
of the structure.
4. Install the unit a little slanted so the back is slightiy lower than the front(about
1/2).
This will force condensed
water to flow to the outside.
5. Install the unit with the bosom about 30"*_60 '' above the floor level.
[] Window Requirements(SK,
1OK Ser_s)
All supporting parts should be secured to fi_
wood, masonry, or metal.
This unit is designed
for installation in
standard
double hung windows
with actual
opening widths from 22" to 36".
The top and bosom window sash must open
sufficiently
to allow a clear vertical
opening of
15" from the bottom of the upper sash to the
window stool.
15" min
Interior wall
18 1/2" min.
(Without framecurtai#)