Toensure t hatthegrill o perates properly, it isrecommended
thattheisland have ventilation onall4 sides asshown i nthe
following i llustration. The ventilation holes s hould beas
diagrammed
toensure a dequate ventilation foryour g rill a nd
island.
Natural Gas Conversion
Natural Gas Pressure Regulator Location
Measurements shown are for attaching the Natural gas pressure
regulator to the enclosure.
20 in? (129.0 cra 2) rain.
ventilation
both sides
11/2" (3.0 era) raax._
5" (12.7 cm) max.
10 in.2 (64.5 cra 2) rain.
ventilation
both sides
"_/_"
(6.0 cra) max.
Proper ventilation is a required based on the above
mentioned specifications
for your grill to operate properly.
LP Gas
LP Gas Pressure Regulator/Hose
Assembly
Location
Measurements
shown are for attaching the LP gas pressure
regulator/hose
assembly to the enclosure.
215/16"
i
\
\
\\\
i
i i
i
/
i
'
i /"
16%"
(42.9 era)
Explosion Hazard
Use a new CSA international
approved
"outdoor"
gas supply
line.
Securely
tighten
all gas connections.
if connected
to LP, have a qualified
person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified
person include:
licensed heating
personnel,
authorized
gas company personnel, and
authorized
service
personnel
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
IMPORTANT: Grill must be connected to a regulated gas supply.