Minimum
Clearances
to Combustible
Surfaces
Using dimensions, prepare cabinet opening.
• Minimum clearance to rearwall is 0 inches.
• Minimum clearance to a vertical right or left side wall is
3 inches.
• Minimum clearance to countertop/cabinet
on each side
is 0 inches.
• Minimum of 30 inches between top of cooking surface
and bottom of an unprotected wood or metal cabinet.
• Minimum of 24 inches between cooking surface and
protected wood or metal cabinet above range. Cabinet
bottom must be protected by at least ¼ inch thick
millboard with not less than No. 28 MSG sheet steel,
.015 inch thick stainless steel, .024 inch thick
aluminum, or .020 inch thick copper.
E
Installing
Side Trim
If desired, optional side trim provided can be installed on
range. Side trim must be installed above counter top level and
tapped down into place.
Side trim can be mounted in several different positions
depending on counter top opening, cabinet structure, and
range features.
Freestanding
with Backsplash
To mount trim flush with front of counter top, use #3 trim
holes and "A" range holes. Trim does not extend the full
length of the cooking surface.
Optional
Mounting
"A" range holes allow an extra 3/8-inch forward
adjustment. Trim holes #1, #2, and #3 allow a 72-inch
adjustment. Trim can be mounted in any desired location
using holes provided.
Side of Range
2
3.
Side Trim
2
Left
23
Side Trim
_30
inches minimum
B
30 inches unprotected/24 inches protected minimum
C
13 inches maximum
D
3 inches minimum (Both Sides)
E
18 inches minimum
Minimum Clearances to Combustible Surfaces
A
A
If the countertop is roll formed, notch the countertop to allow
for overlapping trim.
B
Side trim
Roll Formed Countertop