Minimum Clearances to Combustible
Surfaces
• Minimum clearance to rear wall is 0 inches.
• Minimum clearance to a vertical right or left side
wall is 0 inches.
• Minimum clearance to counter top/cabinet on each
side is 0 inches.
• Minimum of 30 inches between top of cooking
surface and bottom of an unprotected wood or
metal cabinet.
• 24 inches between cooking surface and protected
wood or metal cabinet above range. Cabinet bottom
must be protected by at least ¼ inch thick
millboard with not less than No. 28 MSG sheet
steel, .015 inch thick stainless steel, .024 inch
thick copper.
A
A
A—30 inches minimum
B—30 inches unprotected/24 inches protected minimum
C—13 inches maximum
B
B
C
C

Line Voltage Requirements

Line voltage must not exceed rated voltage. Line voltage
less than rated voltage will result in slow heating. Wiring
system must conform to Underwriters Laboratories, Inc.
standards and National Electrical Code. Installation must
conform to all local, municipal and state building codes,
and local utility regulations. Range must be connected only
to a supply circuit as specified on range name plate.
This range requires 3 wires, 120/240 Volts, 60 Hertz A.C.
See rating plate attached to range for kilowatt rating.
House wiring and fusing must comply with local wiring
codes. If no codes apply, wire according to National
Electrical Codes.

Power Supply Location

Shaded areas show range clearance for electrical
connection.
A
B
A—3 inches
B—7 inches
C—6 inches
D—30
1
/
to 30¼ inches
8
7
C
D