Gas Supply Requirements - Jenn-Air 740-0712 Installation Instructions And Use & Care Manual

Built-in outdoor grills
Table of Contents

Advertisement

Available languages

Available languages

Toensure t hatthegrill o perates properly, it isrecommended
thattheisland have ventilation onall4 sides asshown i nthe
following i llustration. The ventilation holes s hould beas
diagramed toensure a dequate ventilation foryourgrill a nd
island.
20 in? (129.0 crn 2) rain.
_
_
ventilation both s ides - _._\
t
_
5" (12.7 cm) max.
1,/2" ( s.0ore) ma×.----_
I_
10 in.2 (64.5 cm 2) rain.
ventilation
both
sides
"_/2"
(6.0 cm) max.
Proper ventilation is a required based on the above
mentioned specifications
for your grill to operate properly.
LP Gas
LP Gas Pressure
Regulator/Hose
Assembly
Location
Measurements
shown are for attaching the LP gas 3ressure
regulator/hose
assembly to the enclosure.
Natural Gas Conversion
Natural Gas Pressure Regulator Location
Measurements shown are for attaching the Natural gas pressure
regulator to the enclosure.
2_%o" i
"\\\\\\\\\\
\£.
/
//
//
18%" (48.0 crn)i"
/
/
9
-
ITI
--.
i
Explosion
Hazard
Use a new CSA International
approved
"outdoor"
gas supply
line.
Securely
tighten
all gas connections.
If connected to LP, have a qualified
person make sure
gas pressure
does not exceed 11" (28 cm) water
column.
Examples
of a qualified
person
include:
licensed
heating
personnel,
authorized
gas company personnel,
and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
IMPORTANT: Grill must be connected to a regulated gas supply.
8