3.11 WARNING MENU
The EDR provides warning functions allowing signalling upon operation failure. Define the
alarm reactions in the WARNING menu.
3.11.1 FAN FAILURE
WARNING SETUP MENU
FAN FAULT
BUZZER
HDD TEMP.
ALARM OUTPUT
NO HDD
ALARM DURATION
HDD FULL
NETWORK ALARM
EMAIL
Both fans provide failure detection. Define the alarm reactions upon fan failure in this
menu item:
(1) BUZZER:
(2) ALARM OUTPUT:
(3) ALARM DURATION: PERMANENT
(4) NETWORK ALARM:
(5) EMAIL:
ENABLE
1
PERMANENT
NO
NO
By selection "ENABLE", the buzzer is activated upon fan
failure.
Output relay activation.
1:
Output relay
NONE:
No relay reaction upon alarm.
This value cannot be changed, alarm is
automatically switched off after problem has
been solved (fan replacement).
YES:
Network alarm activated (for settings refer
to NETWORK menu)
Network alarm reception requires optional
PowerCon software.
NO:
No network alarm transmission
YES:
Alarm email transmission (for settings refer
to NETWORK menu).
NO:
No email alarm transmission.
- 46 -
EDR910_1610_ma_en_rev1 00