Venting Arrangements; Horizontal Termination (Flex) - Regency Horizon HZ54-NG Owners & Installation Manual

Hide thumbs Also See for Horizon HZ54-NG:
Table of Contents

Advertisement

These venting systems, in combination with the HZ54, have been tested and listed as a direct vent system by Warnock Hersey/Intertek. The location
of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations"
section.
FPI Direct Vent (Flex) System Termination Kits include all the
parts needed to install the HZ54 using a fl exible vent.
FPI Kit #
Length Contains:
#946-615
4 Feet
1)
8" fl exible liner (Kit length)
2)
5" fl exible liner (Kit length)
3)
spring spacers
4)
thimble
#946-618
6 Feet
5)
AstroCap termination cap
6)
screws
7)
tube of Mill Pac
#946-616
10 Feet
8)
plated screws
9)
S.S. screws #8 x 1-1/2" drill point
10) vinyl siding standoff
HZ54 Regency Horizon
TM
Gas Fireplace

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency
®
Direct Vent System
INSTALLATION
Notes:
1) Liner sections should be continuous without any joints
or seams.
2) Only Flex pipe purchased from FPI may be used for Flex
installations.
3) Horizontal vent must be supported every 3 feet.
4) A wall thimble is mandatory for all horizontal terminations
due to high temperatures.