Regency Horizon HZ54-NG Owners & Installation Manual page 23

Hide thumbs Also See for Horizon HZ54-NG:
Table of Contents

Advertisement

INSTALLATION
One 90
o
elbow = Two 45
Option
V
H + H1
A)
2' Min. 4' Max.
B)
3' Max. 6' Max.
C)
4' Max. 8' Max.
D)
5' Max. 9' Max.
E)
6' Max. 10' Max.
Please note minimum 1 foot between 90
required.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment
required.
One 90
o
elbow = Two 45
Option
V
H
V + V1
A)
2' Min.
1' Max. 3' Min.
B)
2' Min.
2' Max. 5' Min.
C)
3' Min.
2' Max. 7' Min.
D)
4' Min.
3 Max. 9' Min.
E)
5' Min.
4' Max. 10' Min. 7' Max.
F)
6' Min.
6' Max. 11' Min. 9' Max.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment required.
22
Horizontal Venting with Two (2) 90
NG and LP
o
elbows.
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet
total vertical and
maximum 10 feet total
horizontal.
o
elbows is
Horizontal Venting with Three (3) 90
NG and LP
o
elbows.
With these options, max.
H + H1
total pipe length is 30 feet
2' Max.
with min. of 11 feet total
4' Max.
vertical and max. 9 feet total
5' Max.
horizontal.
6' Max.
Please note min. 1 foot
o
between 90
elbows is
required.
o
Elbows
o
Elbows
HZ54 Regency Horizon
TM
Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz54-lpHorizon hz54

Table of Contents