INSTALLATION
Description
Attic Insulation Shield 12"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Colinear Flex Connectors
FPI
946-604/P
Simpson Direct Vent -Vent Guard (Optional)
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-606
Starter collar reducer 5" x 8" to 4" x 6-5/8"
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
5" x 8" Venting
(L)
Run (X)
0" (0mm)
5-11/16" (144mm)
6" (152mm)
8-13/16" (224mm)
9" (229mm)
10-15/16" (278mm)
12" (305mm)
13" (330mm)
24" (610mm)
21-7/16" (697mm)
36" (914mm)
29-13/16" (757mm)
48" (1219mm)
38-1/4" (972mm)
20
Simpson
®
Direct Vent Pro
58DVA-IS
N/A
N/A from FPI
N/A
5DT-HKA
58DVA-KHA
5DT-HKB
58DVA-VHA
5DT-VKC
58DVA-VCH
N/A
N/A
N/A
N/A
5DT-HHC
N/A
5DT-HVC
58DVA-SC
5DT-SC
58DVA-F6
5DT-AF6
58DVA-F12
5DT-AF12
58DVA-VSS
5DT-VS
N/A
5DT-VSP
58DVA-SNK14
N/A
58DVA-SNK36 (N/A - FPI)
N/A
58DVA-RD
N/A
N/A
N/A
Rise (Y)
15-5/16" (389mm)
18-7/16" (468mm)
20-9/16" (522mm)
22-11/16" (576mm)
31-1/16" (789mm)
39-7/16" (1002mm)
47-7/8" (1216mm)
Selkirk
Metal-Fab™
Direct Temp™
Sure Seal
N/A
N/A
N/A
N/A
N/A
N/A
5DHT
5DVT
5DSC
5DF
5DF1-2
5DVS
N/A
N/A
N/A
N/A
N/A
946-623/P
AstroCap XL Horizontal Cap
946-506/P
Vent Guard (Optional)
946-625
Vinyl Siding Standoff - AstroCap XL
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
Metal-Fab Sure Seal: www.mtlfab.com
Industrial Chimney Company: www.icc-rsf.com
Note: Horizontal runs of vent must be level, or have a 1/4"
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.
HZ54 Regency Horizon
ICC Excel
Direct
N/A
N/A
N/A
N/A
TM-5VT
TM-5DHT
TM-5HT
TM-5VT
TM-SC
TF-5FA
TF-5FB
TM-VSS
N/A
TM-5ST14
TM-5ST36
TM-5DS
N/A
TM
Gas Fireplace