Specifications; Generator; Transfer Switch - Briggs & Stratton Generator Owner's Manual

Hide thumbs Also See for Generator:
Table of Contents

Advertisement

Available languages

Available languages

Bri_,_s & Stratton Power P roducts Home Generator System
Owners
Manual
Cor_o_ byEc_n_s C u_r H_rner
A switch on the control
panel is labeled "Set Exercise"
(depicted on page 10).The specific day and the specific time
of day this switch is pressed is programmed
into the
control
board memory.This
date and time is then used to
automatically
initiate the system exercise cycle.
To perform
the Set Exercise
procedure:
I.
Choose the day and time you want your Home
Generator
System to exercise.
2.
On that day and time, set the AUTO/OFF/MANUAL
switch to OFF.
3.
Press and hold down the "Set Exercise" switch.The
Diagnostic LED blinks.
4.
Hold the switch down until the Diagnostic
LED stops
blinking. Release the Set Exercise switch.
5,
Set the AUTO/OFF/MANUAL
switch to AUTO.
"Set
Exercise" is complete.
For example, if you press the "Set Exercise" switch on
Sunday morning at I0:00 AM, the unit will run an exercise
cycle the following
Sunday at IO:O0 AM,
NOTE:
"Set Exercise" will only work
if the unit is in the
Automatic
mode and this exact procedure
is followed.The
exerciser
does not need to be re-set if the 15 Amp fuse is
removed or changed.The exerciser
will need to be re-set if
the 12Volt DC battery
is disconnected.
If you want to change the day and time the unit exercises,
simply perform the "Set Exercise" procedure
at the exact
weekday and time you want it to take place.
SPECIFICATIONS
Generator
Model ....................
01768-0
Rated Maximum Power (LP*)...
[0.0 kW
Rated Maximum Load Current:
at 240 Volts ...............
41.7 Amps
at 120Volts ...............
83.3 Amps
Rated AC Voltage ............
120/240 Volts
Rated Frequency ............
60 Hz at 3600 rpm
Phase.....................
Single Phase
Power Factor ...............
1.0
NG Fuel Supply Pressure.....
5-14 in W,C. (I 27-356 mm)
LP Fuel Supply Pressure ......
I 1-14 in V_C. (279-
356 ram)
Normal Operating Range ....
-20°F (-28.8°C) to IO4°F
(40°C)
Output
Sound Level ........
70 dB(A) at 23 ft. (7 rn) at
full load
Shipping Weight ............
482 Ibs.
* Natural gas rating will depend on specific fuel but typical
derates are between IO to 20% off the LP gas rating.
Transfer
Switch
Maximum Circuits ...........
10
Maximum Load/Circuit
from Generator ...........
41.7 Amps
from Load Center ..........
50 Amps
Maximum Watts .............
10,000
/
15

Hide quick links: