8-7-3. Device

Select Device to set the motion zone, sensor input/alarm output conditions, PTZ control and spot setting
conditions.
Alarm Output: Sets the alarm output conditions.
Alarm out No.: Specifies the alarm output terminal number (1~4)
Sensor In: Outputs an alarm signal when the specified sensor terminal receives an input.
Motion On: Outputs an alarm signal when the specified video input receives a motion detection.
Video Loss On: Outputs an alarm signal when a video loss occurs in the specified video input.
Alarm Duration: Set the duration of the alarm output signal.
Error Alarm: Sets whether to output or not an alarm signal when the error condition occurs.
PTZ: Sets the environment for remotely operating PTZ cameras connected to RS485 terminals.
Camera channel designation
Camera: Sets the protocol type for the specified channel.
Speed: Sets the communication speed. The set value applies to all channels.
ID: Sets the camera ID.
Motion: It is necessary to set a detection frame when PARTIAL ZONE is selected. Select the level of
detection sensitivity of the motion sensor. Sensitivity selections: 1~9 (High sensitivity level)
Partial Zone: If selecting Partial Zone, a button is displayed to the right.
Key Tone: Sets On or Off of Key Tone.
Remote Controller ID: Sets an ID number on the supplied remote control for its identification.
Sensor: Specify a sensor input terminal number and set the type.