Bit Manipulation Instructions (Setb, Clrb); Read-Modify-Write Operation - Fujitsu Semiconductor Controller MB89950/950A Hardware Manual

F2mc-8l 8-bit microcontroller
Table of Contents

Advertisement

APPENDIX
B.4

Bit Manipulation Instructions (SETB, CLRB)

Some bits of peripheral function registers include bits that are read by a bit
manipulation instruction differently than usual.
I Read-modify-write operation
By using these bit manipulation instructions, only the specified bit in a register or RAM location can be set
to 1 (SETB) or cleared to 0 (CLRB). However, as the CPU operates on data in 8-bit units, the actual
operation (read-modify-write operation) involves a sequence of steps: 8-bit data is read, the specified bit is
changed, and the data is written back to the location at the original address.
Table B.4-1 "Bus operation for bit manipulation instructions" shows bus operation for bit manipulation
instructions.
Table B.4-1 Bus operation for bit manipulation instructions
CODE
MNEMONIC
A0 to A7
CLRB dir:b
A8 to AF
SETB dir:b
I Read operation upon the execution of bit manipulation instructions
For some I/O ports and for the interrupt request flag bits, the value to be read differs between a normal read
operation and a read-modify-write operation.
G
I/O ports (during a bit manipulation)
From some I/O ports, an I/O pin value is read during a normal read operation, while an output latch value is
read during a bit manipulation. This prevents the other output latch bits from being changed accidentally,
regardless of the I/O directions and states of the pins.
G
Interrupt request flag bits (during a bit manipulation)
An interrupt request flag bit functions as a flag bit indicating whether an interrupt request exists during a
normal read operation. However, 1 is always read from this bit during a bit manipulation. This prevents the
flag from being cleared accidentally by a value of 0 which would otherwise be written to the interrupt
request flag bit when another bit is manipulated.
278
TO
Cycle
Address bus
4
1
N+1
2
dir address
3
dir address
4
N+2
Data bus
RD
dir
0
Data
0
Data
1
Next instruction
0
WR
RMW
1
0
1
1
0
0
1
0

Advertisement