PLC-XF1000 Expand Serial Command Functional Specifications

8.9.19 CF_SHUTRCPROT Command

Command
"CF_SHUTRCPROT_%1" [CR]
"ON" ------------------ Disable RC key from controlling Shutter (Protection On)
%1
"OFF" ----------------- Enable RC key to control Shutter (Protection Off)
Set valid / invalid of RC use on Shutter control function
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.20 CF_SHUTKEYPROT Command

Command
"CF_SHUTKEYPROT_%1" [CR]
"ON" --------- Disable key on the top panel from controlling Shutter (Protection On)
%1
"OFF" -------- Enable key on the top panel to control Shutter (Protection Off)
Set valid / invalid use of key on the top panel on Shutter control function.
Details
(Valid only when in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.21 CF_SHUTH Command

Command
"CF_SHUTH_%1" [CR]
"005"-"180"----------Specify setting time directly
%1
"UP" ------------------ Add 1 minute
"DN" ------------------Decrease 1 minute
Set time of operating shutter management function.
(Valid only when in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10 Other Command

8.10.1 CF_SHUTTER Command

Command
"CF_SHUTTER_%1" [CR]
"OPEN"------------------ Open Shutter
%1
"CLOSE" --------------- Close Shutter
Control OPEN / CLOSE of Shutter (Valid only when in the normal Power ON
Details
status)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
41/72