PLC-XF1000 Expand Serial Command Functional Specifications
8.8 Lamp Command
8.8.1 CF_LAMPH Command
Command
"CF_LAMPH_%1" [CR]
%1
"RSTn" (n=1-2) --------------------------- Reset lamp 1-2 running time
Reset running time of the lamp specified in "n".
Details
(Valid only when it is in the normal Power ON status.)
Acceptable
Response
Unacceptable
8.8.2 CF_LAMPMODE Command
Command
"CF_LAMPMODE_%1" [CR]
"FULL" --------------------------- Set lamp mode to 2-lamp (FULL)
%1
"HALF" --------------------------- Set lamp mode to 1-lamp (HALF)
Select Lamp mode. (Valid only when in the normal Power ON status.)
The value set by this command is stored in EEPROM and the setting remains
Details
effective after the power is turned to ALL OFF status.
On Half mode, one lamp with a fewer used-time light automatically.
Acceptable
Response
Unacceptable
8.8.3 CF_AUTOLAMPCONTRL Command
Command
"CF_AUTOLAMPCONTRL_%1" [CR]
"NORMAL" --------------------- Set lamp control mode to NORMAL
%1
"ECO" --------------------------- Set lamp control mode to ECO
"AUTO" -------------------------- Set lamp control mode to AUTO
Select Lamp control mode. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
35/72