PLC-XF1000 Expand Serial Command Functional Specifications

9.6 Video Status Read Command

9.6.1 CR_SERSYS Command

Command
"CR_SERSYS" [CR]
Get currently selected signal.
Details
Value only when Input is video. (Invalid when Input is computer)
Acceptable
Response
%1
Unacceptable

9.7 Input Read Command

9.7.1 CR_INPUT Command

Command
"CR_INPUT" [CR]
Details
Get selected INPUT No.
Acceptable
Response
%1
Unacceptable

9.7.2 CR_SOURCE Command

Command
"CR_SOURCE" [CR]
Details
Get selected Source
Acceptable
%1
Response
Unacceptable
"000_%1" [CR]
"1080I60"--------------- 1080i 60Hz
"1080I50" -------------- 1080i 50Hz
"1035I" ----------------- 1035i
"720P60" --------------- 720p 60Hz
"720P50" --------------- 720p 50Hz
"575P" ----------------- 575p
"480P" ------------------ 480p
"575I" ------------- 575i (includes composite signal such as PAL)
"480I" -------------480i (includes composite signal such as NTSC)
"NO_SIGNAL" --------------- There is no signal
"?" [CR]
"000_%1" [CR]
"1" – "4"
"?" [CR]
"000_%1" [CR]
"DIGITAL" --------------------- DVI Input is selected
"ANALOG --------------------- ANALOG RGB is selected
"VIDEO" ----------------------- Video Input is selected
"S-VIDEO" -------------------- S-VIDEO Input is selected
"YPBPR" ---------------------- Y/Pb/Pr Input is selected
"SDI1" -------------------------- DF-SDI1 Input is selected
"SDI2"---- ---------------------- DF-SDI2 Input is selected
"HDCP" ----------------------- HDCP Input is selected
"SCART" ---------------------- SCART Input is selected
"HDWL" ----------------------- HD data wireless input is selected
"BLANK" ---------------------- without Source (LAN card)
"NOCARD" --------------------- There is no board inserted
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received