PLC-XF1000 Expand Serial Command Functional Specifications
8.9.7 CF_RSENS Command
Command
"CF_RSENS_%1" [CR]
"BOTH" -------------------------------- Select both front and back receiver of projector
"FRONT" ---------------------------- Select only front receiver of projector
%1
"BACK" ------------------------------------ Select only back receiver of projector
"UP" --------- Switch forward (BOTH → FRONT → BACK → BOTH)
"DN" --------- Switch backward (BACK → FRONT → BOTH → BACK)
Select location of infrared remote receiver of remote control (Available only in the
normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.9.8 CF_P-MANE Command
Command
"CF_P-MANE_%1" [CR]
"OFF" ---------------------------------- Set Power Management to Off
"READY" ----------------------------- Set Power Management to Ready
%1
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ----------------------- Switch forward (Off→Ready→Shut down→Off)
"DN" ---------------------- Switch backward (Off→Shut down→Ready→Off)
Set/Cancel Power Management. (Valid only when in the normal Power ON status.)
Details
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.9.9 CF_P-MANETIME Command
Command
"CF_P-MANETIME_%1" [CR]
"01" - "30" ----------------------- Directly specify setting time by the minute
"UP" ------------------------------- Increment value by 1
%1
"DN" ------------------------------ Decrement value by 1
Set time of Power Management time (Available only in the normal Power ON
Details
status). The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.9.10 CF_ON-STA Command
Command
"CF_ON-STA_%1" [CR]
"ON" --------------------------- Set Power On Start to ON.
"OFF" ------------------------- Set Power On Start to OFF.
%1
"UP" --------------------------- Toggle between ON and OFF.(On→Off→On → - - -)
"DN" --------------------------- Toggle between ON and OFF.(On→Off→On → - - -)
*"UP" and "DN" are exactly same operation.
Set/Cancel Power ON Start (Only valid when it is in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
(Switched in 01→02→ --- → 30 → 01 order)
(Switched in 30→29→ --- → 01 → 30 order)
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
38/72