Screen Control Command; Cf_Screen Command; Cf_Dzcent Command - Sanyo PLC-XF1000 - 12000 Lumens Manual

Rs232 expand serial command
Hide thumbs Also See for PLC-XF1000 - 12000 Lumens:
Table of Contents

Advertisement

PLC-XF1000 Expand Serial Command Functional Specifications

8.7 Screen Control Command

8.7.1 CF_SCREEN Command

Command
"CF_SCREEN_%1" [CR]
Input is
PC signal
%1
Input is
Video signal
Common
in AV/PC
Select screen size. (Valid only when in the normal Power ON status.)
Details
When selected Input does not meet the requirement for the specified %1, return
"101" [CR] and the command is not executed.
Acceptable
Response
Unacceptable

8.7.2 CF_DZCENT Command

Command
"CF_DZCENT_%1" [CR]
%1
"CENT" -------------------- Cancel Digital Zoom (CENT: "CENTER")
Cancel Digital Zoom mode. (Valid only when in the normal Power ON status and
Details
Input for Computer is selected.)
Acceptable
Response
Unacceptable
"NORMAL" ---------------------- Select Normal mode
"TRUE" -------------------------- Select True mode
"WIDE" --------------------------- Select Wide mode
"FULL" --------------------------- Select Full mode
"CUSTOM" ---------------------- Select Custom mode
"DZOOM□UP" ----------------- Expand image size by Digital Zoom
"DZOOM□DN" ---------------- Compress image size by Digital Zoom
"UP" ---------------------------- Select screen size with forward
"DN" ----------------------------- Select screen size with backward
"NORMAL" ---------------------- Select Normal mode
"WIDE" --------------------------- Select Wide mode
"CUSTOM" -----------------------Select Custom mode
"UP" ---------------------------- Select screen size with forward
"DN" ----------------------------- Select screen size with backward
"RST" ---------------------- Reset Screen adjustment
"000" [CR]
"Error Code" [CR]
"000" [CR]
"101" [CR] ----------------- When input is Video
31/72
switching in possible range
(Normal → True → Wide → Full
→ Custom → Normal → ...)
switching in possible range
(Normal →Custom → Full → Wide
→ True → Normal → ...)
switching in possible range
(Normal → Wide →Custom→
Normal → Wide → ...)
switching in possible range
(Normal → Custom→ Wide →
Normal → Custom → ...)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xf1000

Table of Contents