Cf_Rcode Command; Cf_Rsens Command; Cf_P-Mane Command - Sanyo PLC-WM4500/L - 4500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-WM4500/L - 4500 Lumens:
Table of Contents

Advertisement

PLC-WM4500/WM4500L Expand Serial Command Functional Specifications

8.10.23 CF_RCODE Command

Command
"CF_RCODE_%1" [CR]
"001" ------------------------------------ Select Code 1
"002" ------------------------------------ Select Code 2
"003" ------------------------------------ Select Code 3
"004" ------------------------------------ Select Code 4
"005" ------------------------------------ Select Code 5
%1
"006" ------------------------------------ Select Code 6
"007" ------------------------------------ Select Code 7
"008" ------------------------------------ Select Code 8
"UP" ---------- Switch forward (Code1→Code2→Code3 - - - →Code8→Code1)
"DN" --------- Switch backward (Code8→Code7→Code6 - - -→Code1→Code8)
Select Code of Remote Control (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.24 CF_RSENS Command

Command
"CF_RSENS_%1" [CR]
"ALL" ----------------------------------- Select top, front and back receiver of projector
"FRONTTOP" ------------------------ Select front and top receivers of projector
"BACKTOP" -------------------------- Select only back and top receivers of projector
"FRONTBACK" ---------------------- Select only front and back receivers of projector
"FRONT" ------------------------------ Select only front receiver of projector
%1
"TOP" ---------------------------------- Select only top receiver of projector
"BACK" ---------------------------- Select only back receiver of projector
"UP" --------- Switch forward (ALL → FRONTTOP → BACKTOP → FRONTBACK
"DN" --------- Switch backward (BACK → TOP → FRONT →FRONTBACK
Select location of infrared remote receiver of remote control
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.10.25 CF_P-MANE Command

Command
"CF_P-MANE_%1" [CR]
"OFF" ---------------------------------- Set Power Management to Off
"READY" ----------------------------- Set Power Management to Ready
%1
"SHUTDOWN" --------------------- Set Power Management to Shut Down mode
"UP" ----------------------- Switch forward (Off→Ready→Shut down→Off)
"DN" ---------------------- Switch backward (Off→Shut down→Ready→Off)
Set/Cancel Power Management
(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
→ FRONT → TOP → BACK → ALL)
→ BACKTOP → FRONTTOP →ALL→ BACK)
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
43/78