Memory Locations and Replacement Procedures
2.
Refer to Figure
release it from the connector. 
3.
Remove the module from the connector.
Figure B-9
1 Connector arms

Installing the DRAM SIMM on 4H4282-49 or 4H4283-49

To install the memory module, refer to Figure
1.
With the connector arms set in the open position, insert the memory module between 
the connector fingers and push the memory module into the connector until the tabs 
on the two connector arms pull in towards the DRAM SIMM alignment notches. 
2.
Push the DRAM SIMM further into the connector until the two alignment notches and 
the tabs on the two connector arms lock the DRAM SIMM into place.
B-8 Mode Switch Bank Settings and Optional Installations
B‐9. Push the connector arms away from the memory module to 
Note: The ejector arms on this connector are not spring loaded, so they will remain in the
open position until manually closed.

Removing the Existing DRAM SIMM from 4H4282-49 or 4H4283-49

À
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaución: Al trabajar con equipos electrónicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad estática.
Â
2 Memory module
B‐10 and proceed as follows:
Á
À
3