Enterasys Gold Distributed Forwarding Engine 4H4202-72 Hardware Installation Manual page 68

Enterasys networks switch hardware installation guide
Table of Contents

Advertisement

Troubleshooting Checklist
Table 4-1 Troubleshooting Checklist (continued)
Problem
Port(s) goes into
standby for no
apparent reason.
User parameters
(IP address, device
and module name,
etc.) were lost
when the module
power was cycled,
the front panel
OFFLINE/RESET
switch was
pressed.
4-8 Troubleshooting
Possible Cause
Loop condition
detected.
Position of Mode switch
(7), Persistent Data
Reset, was changed
sometime before either
cycling power or
pressing the OFFLINE/
RESET switch, causing
the user-entered
parameters to reset to
factory default settings.
Clear Persistent Data
was set through Local
Management.
The module was moved
either from slot-to-slot
or from chassis-to-
chassis.
Recommended Action
Verify that Spanning Tree is enabled. Refer to the
Enterasys Matrix DFE-Gold Series Configuration
Guide for the instructions to set the type of STA.
Review the network design and delete
unnecessary loops.
If the problem continues, contact Enterasys
Networks for technical support.
Reenter the lost parameters as necessary. Refer
to the Enterasys Matrix DFE-Gold Series
Configuration Guide for the instructions to
configure the device.
If the problem continues, contact Enterasys
Networks for technical support.

Advertisement

Table of Contents
loading

Table of Contents