Installing the Hardware
Table 19. Line card installation notes (Continued)
Minimum
Firmware
SSR-SERC-04-AA
E8.3.0.0
SSR-SERCE-04-AA
E8.3.0.0
76
Restrictions
CLI Setup
Enter the following command at the CLI before
implementing any configurations.
1.
Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #
2.
You may now begin configuring ports on the
SSR-SERC-04-AA. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual for details.
CLI Setup
Enter the following command at the CLI before
implementing any configurations.
1.
Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #
2.
You may now begin configuring ports on the
SSR-SERCE-04-A. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual for details.
Special Instructions
Proper Boot Sequence
•
Firmware loads.
•
The control module for the chassis should indicate
that the SSR-SERC-04-AA was detected and is
operating correctly.
•
The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).
Common Errors
•
The ER16-SERC-04-AA is not inserted properly or
seated completely in the chassis
•
Connectors for the connected lines are not seated
properly.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
Port show port status se.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).
•
System show bootlog
Proper Boot Sequence
•
Firmware loads.
•
The control module for the chassis should indicate
that the SSR-SERCE-04-A was detected and is
operating correctly.
•
The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).
Common Errors
•
The ER16-SERCE-04-A is not inserted properly or
seated completely in the chassis
•
Connectors for the connected lines are not seated
properly.
Helpful CLI Commands for Debugging
•
System show hardware
•
System show version
•
Port show port status se.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).
•
System show bootlog
Enterasys X-Pedition 8000/8600 Getting Started Guide