Hitachi L100DN DeviceNet Series Addendum Read This First Manual page 87

Table of Contents

Advertisement

DeviceNet Network Settings
"P" Group Parameters
Func.
Name
Code
P_41 DeviceNet baud rate
P_42 DeviceNet MAC ID
P_43 DeviceNet control enable
P_44 DeviceNet comm watchdog timer
P_45 Inverter action on DeviceNet
comm error
P_46 DeviceNet polled I/O: Output
instance number
P_47 DeviceNet polled I/O: Input
instance number
P_48 Inverter action on DeviceNet idle
mode
P_49 DeviceNet motor poles setting for
RPM
Supported Services, DeviceNet Class ID = 109
Service Name
Get_Attribute_Single
Set_Attribute_Single
DeviceNet Class ID = 109
Inst Attr Size
1
141
1
1
142
1
1
143
1
2
144
2
1
145
1
1
146
1
1
147
1
1
148
1
1
149
1
Code
0Eh
10h
L100DN Inverter
Range
Scaling
0 125 kbaud
1 250 kbaud
2 500 kbaud
0 – 63
1
0 Disable
1 Enable
0.00 – 99.99 sec.
100
0 Trip
1 Decel and trip
2 Hold last speed
3 Free run stop
4 Decel and stop
20, 21, 100
1
70, 71, 101
1
0 Trip
1 Decel and trip
2 Hold last speed
3 Free run stop
4 Decel and stop
0 – 38 (even
1
numbers only)
Description
87
Get/
Set
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S

Advertisement

Table of Contents
loading

Table of Contents