Network Register Map
"A" Group Parameters
Func.
Code
A_42 Manual torque boost value
A_43 Manual torque boost frequency
adjustment
A_44 V/f characteristic curve selection
A_45 V/f gain setting
A_51 DC braking enable
A_52 DC braking frequency setting
A_53 DC braking wait time
A_54 DC braking force during deceler-
ation
A_55 DC braking time for deceleration
A_61 Frequency upper limit setting
A_62 Frequency lower limit setting
A_63,
Jump (center) frequency setting
A_65,
A_67
A_64,
Jump (hysteresis) frequency
A_66,
width setting
A_68
A_81 AVR function select
A_82 AVR voltage select
A_92 Acceleration (2) time setting
A_93 Deceleration (2) time setting
Name
Inst Attr Size
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
DeviceNet Class ID = 101
Range
142
1
0 – 99%
143
2
0.0 – 50.0%
144
1
0 Constant torque
1 Reduced torque
145
1
50 – 100%
151
1
0 Disable
1 Enable
152
2
0.5 – 10.0Hz
153
1
0.1 – 5.0 sec.
154
1
0 – 100%
155
2
0.1 – 60.0 sec.
161
2
0.0 Disable
0.5 – 360.0Hz
162
2
0.0 Disable
0.5 – 360.0Hz
163
2
0.0 – 360.0Hz
165
2
167
2
164
2
0.0 – 360.0Hz
166
2
168
2
181
1
0 AVR enabled
1 AVR disabled
2 AVR enabled
except during
deceleration
182
1
0 200V
1 220V
2 230V
3 240V
4 380V
5 400V
6 415V
7 440V
8 460V
192
2
0.1 – 3000.0 sec.
193
2
0.1 – 3000.0 sec.
Get/
Scaling
Set
1
G/S
10
G/S
G/S
1
G/S
G/S
100
G/S
10
G/S
1
G/S
10
G/S
100
G/S
100
G/S
100
G/S
100
G/S
G/S
G/S
10
G/S
10
G/S