Hitachi L100DN DeviceNet Series Addendum Read This First Manual page 84

Table of Contents

Advertisement

84
Network Register Map
Fine Tuning Functions
"B" Group Parameters
Func.
Code
B_01 Selection of automatic restart
mode
B_02 Allowable under-voltage power
failure time
B_03 Retry wait time before motor
restart
B_12 Level of electronic thermal
setting
B_13 Electronic thermal characteristic
B_21 Overload restriction operation
mode
B_22 Overload restriction setting
B_23 Deceleration rate at overload
restriction
Name
Inst Attr Size
1
1
1
1
1
1
1
1
DeviceNet Class ID = 103
Range
101
1
0 Alarm output
after trip, no
automatic restart
1 Restart at 0Hz
2 Resume opera-
tion after freq.
matching
3 Resume
previous freq. after
freq. matching,
then decelerate to
stop and display
trip info.
102
2
0.3 – 25.0 sec.
103
2
0.3 – 100.0 sec.
112
2
5% to 120% rated
current, in A
113
1
0 Reduced torque
1 Constant torque
2 Reduced
torque2
121
1
0 Disabled
1 Enabled for
acceleration and
constant speed
2 Enabled for
constant speed
only
122
2
50% to 150%
rated current, in A
123
2
0.3 – 30.0
Get/
Scaling
Set
G/S
10
G/S
10
G/S
10
G/S
G/S
G/S
100
G/S
10
G/S

Advertisement