Hitachi L100DN DeviceNet Series Addendum Read This First Manual page 80

Table of Contents

Advertisement

80
Network Register Map
"F" Group Parameters and
Basic Inverter Data
Func.
Code
F_01 Output frequency setting
F_02 Acceleration (1) time setting
F_03 Deceleration (1) time setting
F_04 Keypad Run key routing
Input terminal functions monitor1
Input terminal functions monitor2
Input terminal functions setting1
Input terminal functions setting2
Output terminal functions
monitor
Service Name
Reset
Get_Attribute_Single
Set_Attribute_Single
Name
Inst Attr Size
1
1
1
1
1
1
1
1
1
Supported Services, DeviceNet Class ID = 100
Code
05h
Initializes all parameters to factory default values,
excluding P_41 DeviceNet baud rate and P_42
DeviceNet MAC ID
0Eh
10h
DeviceNet Class ID = 100
Range
159
2
0 – 360Hz
160
2
0.1 – 3000.0 sec.
161
2
0.1 – 3000.0 sec.
162
1
0 forward
1 reverse
2 [F/R] terminal
163
2
See EDS file
164
2
See EDS file
165
2
See EDS file
166
2
See EDS file
167
1
See EDS file
Description
Get/
Scaling
Set
100
Get
10
Get
10
Get
Get
Get
Get
Get
Get
Get

Advertisement

Table of Contents
loading

Table of Contents