"D" Group Parameters and
Basic Inverter Data
Func.
Name
Code
D_06 Intelligent output terminal status
D_07 Scaled output frequency monitor
D_16 Cumulative operation RUN time
monitor
P–N voltage monitor
Rate of BRD loading
Rate of electronic thermal
loading
Trip count
D_08 Trip event monitor (nth trip)
Output frequency at trip point
Motor current at trip point
DC bus voltage at trip point
Cumulative operation RUN time
at trip point
D_09 Trip event monitor (nth-1 trip)
Output frequency at trip point
Motor current at trip point
DC bus voltage at trip point
Cumulative operation RUN time
at trip point
D_09 Trip event monitor (nth-2 trip)
Output frequency at trip point
Motor current at trip point
DC bus voltage at trip point
Cumulative operation RUN time
at trip point
DeviceNet Class ID = 100
Inst Attr Size
Range
1
109
1
0 open
1 close,
Bit 0 = terminal 11
Bit 1 = terminal 12
1
110
4
0.00–35964.00Hz
(= 360 * 99.9)
1
115
4
0 – FFFFFFh
(hex) hours
1
118
2
0.0 – 6553.5V
1
119
1
0 – 100%
1
120
1
0 – 100%
1
121
1
0 – 255
1
122
1
00 to 60 (see Ch.6
in manual)
1
123
2
0.01 – 360Hz
1
124
2
0.00 – 655.35A
1
125
2
0.0 – 6553.5V
1
126
4
0 – FFFFFFh
(hex) hours
1
128
1
00 to 60 (see Ch.6
in manual)
1
129
2
0.01 – 360Hz
1
130
2
0.00 – 655.35A
1
131
2
0.0 – 6553.5V
1
132
4
0 – FFFFFFh
(hex) hours
1
134
1
00 to 60 (see Ch.6
in manual)
1
135
2
0.01 – 360Hz
1
136
2
0.00 – 655.35A
1
137
2
0.0 – 6553.5V
1
138
4
0 – FFFFFFh
(hex) hours
L100DN Inverter
Get/
Scaling
Set
Get
100
Get
1
Get
10
Get
1
Get
1
Get
1
Get
Get
100
Get
100
Get
10
Get
1
Get
Get
100
Get
100
Get
10
Get
1
Get
Get
100
Get
100
Get
10
Get
1
Get
79

Advertisement

Table of Contents
loading

Table of Contents