General Safety Information; Installation - Campbell Hausfeld FP204020 Operating Instructions And Parts Manual

Oilless compressors
Table of Contents

Advertisement

Available languages

Available languages

Oilless Compressors
General Safety
DANGER
!
Information
(Continued)
Never attempt to repair
or modify a tank!
3. Only persons well acquainted with
Welding, drilling or any
these rules of safe operation should
other modification will weaken the
be allowed to use the compressor.
tank resulting in damage from rupture
4. Keep visitors away and NEVER allow
or explosion. Always replace worn or
damaged tanks.
children in the work area.
5. Wear safety glasses
WARNING
and use hearing
!
protection when
13. Tanks rust from moisture build-up,
operating the pump
which weakens the tank. Make sure
or unit.
to drain tank daily and inspect
6. Do not stand on or use the pump or
periodically for unsafe conditions
unit as a handhold.
such as rust formation and
7. Before each use, inspect compressed
corrosion.
air system and electrical components
14. Fast moving air will stir up dust and
for signs of damage, deterioration,
debris which may be harmful. Release
weakness or leakage. Repair or
air slowly when draining moisture or
replace defective items before using.
depressurizing the compressor system.
8. Check all fasteners at frequent
intervals for proper tightness.
SPRAYING PRECAUTIONS
WARNING
!
WARNING
!
Motors, electrical
Do not spray flammable
equipment and controls
materials in vicinity of
can cause electrical arcs
open flame or near
that will ignite a flammable gas or
ignition sources including the
vapor. Never operate or repair in or
compressor unit.
near a flammable gas or vapor. Never
store flammable liquids or gases in the
15. Do not smoke when spraying paint,
vicinity of the compressor.
insecticides, or other flammable
substances.
CAUTION
!
16. Use a face mask/
Compressor parts may
respirator when
be hot even if the unit
spraying and spray in
is stopped.
a well ventilated area
to prevent health and
9. Keep fingers away from a running
fire hazards.
compressor; fast moving and hot
17. Do not direct paint or other sprayed
parts will cause injury and/or burns.
material at the compressor. Locate
10. If the equipment should start to
compressor as far away from the
abnormally vibrate, STOP the
spraying area as possible to
engine/motor and check
minimize overspray accumulation
immediately for the cause. Vibration
on the compressor.
is generally a warning of trouble.
18. When spraying or cleaning with
11. To reduce fire hazard, keep
solvents or toxic chemicals, follow
engine/motor exterior free of oil,
the instructions provided by the
solvent, or excessive grease.
chemical manufacturer.
Never remove or
WARNING
!
attempt to adjust
safety valve. Keep safety valve free
from paint and other accumulations.
www.chpower.com

Installation

LOCATION
It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than 100°F.
A minimum clearance of 18 inches
between the compressor and a wall is
Drain liquid from
required because objects could obstruct
tank daily.
air flow.
Do not locate the
CAUTION
!
compressor air
inlet near steam, paint spray, sandblast
areas or any other source of
contamination. This debris will damage
the motor.
GROUNDING INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 1. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.
Grounding
Pin
TEST
RESET
Grounded Outlet
Figure 1 - Grounding Method
DANGER
!
Improper use of
grounding plug can
result in a possible risk
of electrical shock!
2
Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio
Sírvase darnos la siguiente información:
-Número del modelo
-Número de Serie (de haberlo)
-Descripción y número del repuesto según la lista de repuestos
20
18
16
1
19
7
3
4
6
5
Liste de Repuestos
No. de
Numero
Ref. Descripción
de pieza
1
Cubierta con mango
FP204001AV
2
Ensamblaje del mango
FP204002AV
3
Manómetro del tanque
FP204012AV
4
Regulador
FP204013AV
5
Múltiple
FP204003AV
6
Válvula de seguridad
V-215102AV
7
Interruptor
FP200343AV
8
Llave de drenaje
D-1403
9
Ensamblaje de la bomba/motor
(incluye el cable)
FP204004AV
10a
Tablero del circuito
(Modelos FP204000, FP204500) FP204005AV
10b Tablero del circuito
(Modelos FP204100, FP204700) FP204122AV
FP204020, FP204100, FP204501, FP204700
Puede escribirnos a:
The Campbell Group / Attn: Parts Department
100 Production Drive
Harrison, OH 45030 U.S.A.
15
14
12
17
13
2
21
22
10a
14
10b
15
13
11
8
No. de
Numero
Ctd.
Ref. Descripción
de pieza
1
11
Presostato
FP200354AV
1
12
Tubo de salida
s
1
13
Accesorio de compresión
s
1
14
Tuerca de compresión
FP200353AV
1
15
Casquillo de compresión
1
16
Tornillos de la tapa -
Artículo estándar
1
M6-1.0 x 20
de ferretería
1
17
Manguera de 7,6 m (25 pies)
MP285100AV
18
Juego de herramientas (5 piezas)FP204008AV
1
19
Juego válvula de chequeo
FP204010AV
20
Storage cover
FP204007AV
1
21
Fusible
FP200352AV
22
Ventilador
FP204006AV
1
Juego del tubo de salida
s
(incluye Nº 12, 13, 14 & 15)
FP200339AV
Juego de etiqueta adhesiva
(no se muestra)
FP204011AV
23 Sp
9
Ctd.
1
1
2
2
2
4
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp204501Fp204100Fp204700

Table of Contents