Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These units
operate without oil. Compressed air
from this unit will contain moisture.
Install a water filter or air dryer if
application requires dry air.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
an imminently hazardous situation which,
if not avoided, WILL result in death or
serious injury.
a potentially hazardous situation
which, if not avoided, COULD result in
death or serious injury.
a potentially hazardous situation which,
if not avoided, MAY result in minor or
moderate injury.
important information, that if not
followed, MAY cause damage to
equipment.
CALIFORNIA PROPOSITION 65
This product or its power
cord contains chemicals
known to the State of
California to cause cancer
and birth defects or other reproductive
harm. Wash hands after handling.
dust when you cut, sand, drill or grind
materials such as wood, paint, metal,
concrete, cement, or other masonry.
This dust often contains chemicals
known to cause cancer, birth defects,
or other reproductive harm. Wear
protective gear.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2010
STOP!
Record the Model No., Serial No. and
date of purchase located on the base
Danger
indicates
below the pump in the space below.
Model No. ____________________
Date Code ____________________
Warning
indicates
Date of purchase _________________
Retain these numbers for future
reference.
Caution
indicates
Unpacking
Notice
After unpacking the unit, inspect
indicates
carefully for any damage that may
have occurred during transit. Make
sure to tighten fittings, bolts, etc.,
before putting unit into service. In case
of questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance.
Have the date code, model number,
and parts list (with missing parts circled
before calling.)
You can
unit if damaged during shipping, handling
create
or use. Damage may result in bursting and
cause injury or property damage.
Attach it to this manual or file it for safekeeping.
FP2090, FP2091, FP2094 Series
DO NOT RETURN THE
PRODUCT TO THE
RETAILER! CALL
1-800-543-6400
Do not
operate
Breathable Air Warning
This compressor/pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application
of air for human consumption,
the air compressor/pump will
need to be fitted with suitable
in-line safety and alarm
equipment. This additional
equipment is necessary to
properly filter and purify the air
to meet minimal specifications
for Grade D breathing as
described in Compressed Gas
Association Commodity
Specification G 7.1 - 1966, OSHA
29 CFR 1910. 134, and/or
Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not
simultaneously used, existing
warranties shall be voided, and
the Manufacturer disclaims any
liability whatsoever for any
loss, personal injury or damage.
IN617403AV 1/10

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld FP2090 Series

  • Page 1: Operating Instructions

    Wear protective gear. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. © 2010 FP2090, FP2091, FP2094 Series DO NOT RETURN THE PRODUCT TO THE STOP! RETAILER! CALL 1-800-543-6400 Record the Model No., Serial No.
  • Page 2: General Safety Information

    General Safety Information Since the air compressor and other components used (filters, lubricators, hoses, etc.), make up a high pressure pumping system, the following safety precautions must be observed at all times: 1. Read all manuals included with this product carefully.
  • Page 3: Operation

    Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion. Figure 4 FP2090, FP2091, FP2094 Series Handle Air Outlet Drain Valve Motor Reset - (not shown, located inside motor).
  • Page 4: Maintenance

    Operation (Continued) 7. Unplug power cord. BEFORE EACH STARTUP OPERATING PROCEDURE 1. Turn switch to OFF ( O ) position and plug in power cord. 2. Turn regulator knob counterclockwise to close air flow. 3. Turn switch to ON ( I ) position. 4.
  • Page 5: Troubleshooting Chart

    2. High humidity Safety valve pops open 1. Defective pressure switch 2. Defective safety valve FP2090, FP2091, FP2094 Series Corrective Action 1. Make sure compressor is plugged in and switch is ON 2. Check circuit breaker or fuse at electrical panel.
  • Page 6: Limited Warranty

    8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Provide dated proof of purchase and maintenance records. B. Call Campbell Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser. C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
  • Page 7: Directives De Sécurité

    En cas de dommage ou de parties manquantes, S.V.P. composer le 1-800-543-8622 pour demander conseil. 7 Fr Série FP2090, FP2091, FP2094 Avertissement d’Air Respirable Ce compresseur/pompe n’est pas équipé pour et ne devrait pas être utilisé “comme soi” pour fournir de l’air respirable.
  • Page 8: Généralités Sur La Sécurité

    Compresseur Sans Huile Généralités sur la Sécurité Puisque le compresseur d’air et les autres pièces détachées (filtres, graisseurs, tuyaux, etc.) font partie d’un système de haute pression, il est nécessaire de suivre les précautions suivantes : 1. Lire attentivement tous manuels compris avec ce MANUEL produit.
  • Page 9 épuisé, le pressostat mettra en marche le compresseur automatiquement lorsque la pression atteint la valeur de redémarrage / enclenchement. 9 Fr Série FP2090, FP2091, FP2094 Manche Sortie d’aire Robinet de Purge Régulateur - Le régulateur sert à régler la pression d’air à...
  • Page 10 Compresseur Sans Huile Fonctionnement (Suite) Réinitialisation du moteur - (non illustré, se trouve à l'intérieur du moteur).Conçu pour empêcher le moteur de surchauffer. Le moteur a un protecteur de réinitialisation automatique. Pour réinitialiser après le refroidissement du moteur, tourner l’interrupteur à la position « OFF » (arrêt) puis à...
  • Page 11: Guide De Dépannage

    Entretien (Suite) Le moteur doit se refroidir avant que le démarrage soit possible. CONCLUSION DU TRAVAIL/ENTREPOSAGE 1. Mettre l’interrupteur ON / OFF ( I / O ) à la position « OFF » (ARRÊT) ( O ). 2. Débrancher le cordon d’alimentation Guide de Dépannage Symptôme Cause(s) Possible(s)
  • Page 12: Garantie Limitée

    2. GARANTIE ACCORDÉE PAR (GARANT) : Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone : (800) 543-6400 3. BÉNÉFICIAIRE DE CETTE GARANTIE (ACHETEUR) : L’acheteur original (sauf en cas de revente) du produit Campbell Hausfeld. 4. PRODUITS COUVERTS PAR CETTE GARANTIE : Ce compresseur d’air Campbell Hausfeld.
  • Page 13: Medidas De Seguridad

    En el caso de que haya daño o partes que faltan, haga el favor de llamar al 1-800-543-8622 para obtener ayuda. 13 Sp Serie FP2090, FP2091, FP2094 Advertencia sobre el aire respirable Este compresor/cabezal no viene listo de fábrica para suministrarle aire respirable.
  • Page 14: Instalación

    Compresores Sin Aceite Informaciones Generales de Seguridad Como el compresor de aire y otros componentes usados (filtros, lubricadores, mangueras, etc.), forman parte de un sistema de bombeo de alta presión, deberá seguir las siguientes medidas de seguridad todo el tiempo: 1.
  • Page 15 Al girar la perilla en sentido antihorario (hacia la izquierda) la presión de aire a la salida disminuye. 15 Sp Serie FP2090, FP2091, FP2094 Mango Salida de aire Llave de drenaje...
  • Page 16: Mantenimiento

    Compresores Sin Aceite Funcionamiento (Continuación) Reinicio del motor - (no se muestra, ubicado dentro del motor). Diseñado para evitar que el motor se recaliente. El motor tiene un protector de reinicio automático. Para reiniciar una vez que se haya enfriado el motor, coloque el interruptor en la posición de apagado (OFF) y luego en la posición de encendido (ON).
  • Page 17 Cuando drene el tanque, la presión debe estar por debajo de 10 psi. 17 Sp Serie FP2090, FP2091, FP2094 5. Debe desconectar la manguera del compresor y colgarla con los extremos hacia abajo para que toda humedad se drene.
  • Page 18: Guía De Diagnóstico De Averías

    Compresores Sin Aceite Guía de diagnóstico de averías Problema Posible(s) Causa(s) El compresor 1. El interruptor está en la posición OFF (apagado) no funciona 2. No hay corriente eléctrica en el tomacorriente de la pared 3. El compresor alcanzó la presión de corte automático 4.